  remote seal type differential pressure transmitter the fcx?aiii differential pressure transmitter accurately measures differential pressure, liquid level or gauge pres- sure and transmits a proportional 4 to 20ma signal. the transmitter utilizes a unique micromachined capacitance sili- con sensor with state-of-the-art microprocessor technology to provide exceptional performance and functionality. totally welded construction of the seals assures excellent reliability in high temperature and highly corrosive process conditions. 1. high accuracy 0.2% accuracy for all calibrated spans is a standard fea- ture for all dp models covering 0.32kpa {3.2mbar} range to 500kpa {5bar} high differential pressure range. 0.1% accuracy is available as option. fuji?s micro-capacitance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjust- ment. 2. minimum environmental in uence the ?advanced floating cell? design which protects the pressure sensor against changes in temperature, static pressure, and overpressure substantially reduces total measurement error in actual ? eld applications. 3. fuji/hart bilingual communications protocol fcx?aiii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart ? . any hart ? compatible devices can communicate with fcx?aiii . 4. application exibility various options that render the fcx?a iii suitable for al- most any process applications include: ? full range of hazardous area approvals ? built-in rfi ? lter and lightning arrester ? 5-digit lcd meter with engineering unit ? stainless steel electronics housing ? wide selection of materials ? high temperature, high vacuum seals 5. programmable output linearization function in addition to linear and square root, output signal can be freely programmable. (up to 14 compensated points at approximation.) 6. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 7. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. remark : to mini mize environmental in? uence, span should be greater than 1/40 of the max. span in most applications. ? lower limit of static pressure (vacuum limit), silicone ? ll sensor: see fig. 1 fluorinated ? ll sensor: atmospheric pressure ? the maximum span of each sensor can be converted to different units using factors as below. 1mpa =10 3 kpa=10bar=10.19716kgf/cm 2 =145.0377psi 1kpa=10mbar=101.976mmh 2 o=4.01463h 2 o overrange limit: to maximum static pressure limit output signal: 4 to 20ma dc (linear or square root) with digital signal superimposed on the 4 to 20ma signal power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. features functional speci cations service: liquid, gas, or vapour static pressure, span, and range limit: } up to ? ange rating f k d 3 f k d 5 f k d 6 +/? 32 {+/? 320} +/? 130 {+/? 1300} +/? 500 {+/? 5000} 0.32 { 3.2 } 1.3 { 13 } 5 { 50 } 32 { 320 } 130 { 1300 } 500 { 5000} min. type range limit [kpa] {m bar} span limit [kpa] (m bar} max. static pressure specifications data sheet fkd ... 5 EDSX6-136H aug. 10, 2011 date
2 fkd ... 5 process: fill ? uid code in the 13th digit of ?code symbols? process temperature lower limit of static press. fluorinated oil w, a and d ?20 to 120c atmospheric pressure silicone oil h ?15 to 250c j 20 to 300c y and g ?40 to 180c 2.7kpa abs {20mmhg abs} s ?15 to 250c t 20 to 300c k ?15 to 200c 0.13kpa abs {1mmhg abs} or more storage: ?40 to +90c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con? gured. note: hhc?s version must be higher than 7.0 (or fxw 1? 4), for fcx?a iii . local con gurator with lcd display (option): local con? gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con? gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v ? v ? engineering unit vvvv range limit v ? v ? measuring range vvvv damping vvvv output mode linear vvvv square root vvvv burnout direction vvvv calibration vvvv output adjust ? v ? v data v ? v ? self diagnoses v ? v ? printer (in case of fxw with printer option) v ??? external switch lock vvvv transmitter display vvvv linearize vv ?? rerange vvvv saturate current vvvv write protect vvvv history ? calibration history ? ambient temperature history v v v ? v v v ? programmable output linearization function: output signal can be characterized with ?14 points linear approximation function? from hhc (1) . emc conformity: en61326-1: 2006 (note) (1) hhc: hand held communicator load limitations: see ? gure below 2000 [] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3 note: for communication with hhc (1) (model: fxw), min. of 250 ? is required. hazardous locations: table 2 zero/span adjustment: zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con? gurator unit with lcd display. the time constant is adjustable between 0.06 to 32 seconds. zero elevation/suppression: ?100% to +100% of url normal/reverse action: selectable from hhc (1) indication: analog indicator or 5-digit lcd meter, as speci? ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?output hold?, ?output overscale? or ?output underscale? modes. ?output hold?: output signal is hold as the value just before failure happens. ?output overscale?: adjustable within the range 20.0ma to 22.5ma from hhc (1) ?output underscale?: adjustable within the range 3.2ma to 4.0ma from hhc (1) 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout output limits conforming to namur ne43 by order. loop-check output: transmitter can be con? gured to provide constant signal 3.2ma through 22.5ma by hhc (1) . temperature limit: ambient: ?40 to + 85c (?20 to + 80c for lcd indicator) (?40 to + 60c for arrester option) (?10 to + 60c for ? uorinated oil ? ll transmitter) (?10 to + 85c for silicone oil ?h?, ?s?, ?k?) * ) (+ 20 to + 85c for silicone oil ?j?, ?t?) * ) *) in case of capillary length is more than 7m, max temperature is +55c. for explosionproof units (? ameproof or intrinsic safety), ambient temperature must be within the limits speci- ? ed in each standard.
3 dielectric strength: 500v ac, 50/60hz 1 min., between cir- cuit and earth. insulation resistance: more than 100m? at 500v dc. internal resistance for external eld indicator: 12? or less physical speci cations electrical connections: g 1 /2 , 1 /2 -14 npt, pg13.5, or m20 1.5 conduit, as speci? ed. process connections: jis, ansi, or din raised face ? anges. jis: 10k80a, 10k100a, 30k80a, or 30k100a ansi: 150lb 3", 150lb 4", 300lb 3", or 300lb 4" din: pn40 dn80 or pn16 dn100 see outline diagram for detailed dimensions. diaphragm extension: 0, 50, 100, 150, or 200mm as speci? ed. (see model code. extended diaphragm is available only with 316l stainless steel or hastelloy-c diaphragm) process-wetted parts material: diaphragm: 316l stainless steel, hastel- loy-c, monel, tantalum, tita- nium or zirconium flange face: 316 stainless steel, hastelloy- c lining monel lining, or tantalum lin- ing extension: 316 stainless steel or hastelloy- c non-wetted parts material: electronics housing: low copper die-cast aluminum alloy ? nished with polyester coating (standard), or 316 stainless steel (astm cf8m), as speci? ed. capillary: in case of 11th code ?d, e, f, l, m, n, p?, pe armored stainless steel. in case of 13th code ?q, r, s, t, v, w, x?, stainless steel armored stainless steel. mounting ? ange: 304 stainless steel or carbon steel fill ? uid: silicone oil (standard) or ? uori- nated oil mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a) pipe using mount- ing bracket, direct wall mounting mass {weight}: transmitter approximately 12 to 31kg without options. add; 0.5kg for mounting bracket 4.5kg for stainless steel housing option 1.5kg per 50mm extension of dia- phragm performance speci cations reference conditions, silicone oil ? ll, 316ss isolating diaphragms, 4 to 20ma analog output in linear mode. accuracy rating: (including linearity, hysteresis, and re- peatability) (standard) for spans greater than 1 /10 of url: 0.2% of span for spans below 1 /10 of url: (option) (code; 21th digit h,k) for spans greater than 1 /10 of url: 0.1% of span for spans below 1 /10 of url: stability: 0.2% of upper range limit (url) for 10 years. temperature effect (*): effects per 28c change between the limits of ?40c and +85c (standard) zero shift: 0.35% of url total effect: 0.5% of url (option) (code; 21th digit j,k) zero shift: 0.3% of url total effect: 0.4% of url note: * excluding effect by temperature difference between the seals. static pressure effect: zero shift; 0.2% of url / 1mpa span shift: ?0.2% of calibrated span / 1mpa overrange effect: zero shift; 0.1% of url for ? ange rating pressure supply voltage effect: less than 0.005% of calibrated span per 1v update rate: 60 msec step response: (without electrical damping) 0.1+0.1 % of span 0.1 ? url span ( ) 0.05+0.05 % of span 0.1 ? url span ( ) range code ?3? ?5? ?6? time constant (at 23c) 2 s 1.7 s 1.7 s dead time 0.12 s
4 fkd ... 5 optional features indicator: a plug-in analog indicator (2.5% accuracy). an optional 5-digit lcd meter with engi- neering unit is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 50s) oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the ? ll ? uid is ? uorinated oil. chlorine service: oil-free procedures as above. includes ? uorinated oil for ? ll. degreasing: process-wetted parts are cleaned, but the ? ll ? uid is standard silicone oil. not for use on oxygen or chlorine measurement. vacuum service: special silicone oil and ? lling procedure are applied. see fig. 1, fig. 2. optional tag plate: an extra stainless steel tag for customer tag data is wired to the transmitter. coating of cell: cell` s surface is ? nished with epoxy/poly- urethane double coating. specify if envi- ronment is extremely corrosive. accessories hand-held communicator: (model fxw, refer to data sheet no. eds 8-47) fig. 2 r elation between process temperature and operating pressure silicone (code y,g) silicone (code s) operating area 101 {1010} 53.3 {533} 13.3 {133} 2.7 {27} [kpa abs] {mbar abs} operating pressure ?40 ?15 60 20 85 120 180 230 250 300 process temperature [c] silicone (code t) sealing liquid:silicone (code k) operating area non-operating area 101 {1010} 0.27 {2.7} 0.13 {1.3} [kpa abs] {mbar abs} operating pressure 200 ?15 100 process temperature [c] fig. 1 relation between process temperature and operating pressure
5 code symbols g1/2 t type 1/2-14npt t type pg 13.5 t type m20 1.5 t type g1/2 l type 1/2-14npt l type pg 13.5 l type m20 1.5 l type mounting flange 304 stainless steel carbon steel 316 stainless steel none (wafer type) 0.32.... 32 {3.2..... 320} 1.3...... 130 {13...... 1300} 5......... 500 {50...... 5000} diaphragm 316l stainless steel hastelloy-c 316l stainless +au coating hastelloy-c monel tantalum titanium zirconium description note note 2 note 3 note 1 digit 4 5 7 6 8 4567 123 f0 5 kd 89 10 11 12 13 14 15 21 digit no. of code 5 6 7 8 s t v w 0 1 2 3 4 5 6 7 8 9 m r a b c d e f g h j k s t u v w x p q 3 5 6 v a b c d h j w m t p r flange size and rating jis 10k 80a jis 10k 100a jis 30k 80a jis 30k 100a ansi/jpi 150lb 3" ansi/jpi 150lb 4" ansi/jpi 300lb 3" ansi/jpi 300lb 4" din pn16/40 dn80 din pn16 dn100 jis 20k 80a ansi/jpi 600lb 3b jis 10k 80a jis 10k 100a jis 30k 80a jis 30k 100a ansi/jpi 150lb 3" ansi/jpi 150lb 4" ansi/jpi 300lb 3" ansi/jpi 300lb 4" din pn16/40 dn80 din pn16 dn100 jis 10k 80a ansi/jpi 150lb 3b ansi/jpi 150lb 4b ansi/jpi 300lb 3b ansi/jpi 300lb 4b ansi/jpi 600lb 3b 3 inch wafer 4 inch wafer flange face 316 stainless steel hastelloy-c 316 stainless steel 316 stainless steel monel tantalum titanium zirconium diaph. extension [mm] 0 50 100 150 200 0 0 0 0 0 0 0 (*2) (*3) note 1: (*1) 100: 1 turn down is possible, but should be used at a span greater than 1 /40 of the maximum span for better performance. note 2: (*2) available for 5th digit code "1", "3", "5", "7", "b", "d", "f", "h", "k", " q", "u", "w", when 13th digit code "s", "t", "k". note 3: (*3) available for 6th code "5", "6" and 5th code "0", "2", "4", "6", "8", "a", "c", "e", "g", "j", "p", "m", "r", "s", "t", "w". 5
6 fkd ... 5 none (for ordinary locations) tiis, flameproof (cable gland seal) (*11) tiis, intrinsic safety fm, flameproof (or explosionproof) (*14) fm, intrinsic safety and nonincentive fm combined of flameproof and intrinsic safety (*14) atex flameproof (*13) atex intrinsic safety atex type n atex combined of flameproof and intrinsic safety (*13) iecex scheme, flameproof (*13) iecex scheme, intrinsic safety csa, flameproof (or explosionproof) (*14) csa, intrinsic safety and nonincentive nepsi, flameproof (or exprosionproof) nepsi, intrinsic safety nepsi, combined of flameproof and intrinsic safety capillary mounting bracket armor of capilary 1.5 m 304 stainless steel pe (*4) 3 304 stainless steel pe (*4) 5 304 stainless steel pe (*4) 6 304 stainless steel pe (*4) 7 304 stainless steel pe (*4) 8 304 stainless steel pe (*4) 10 304 stainless steel pe (*4) 1.5 304 stainless steel stainless steel (*5) 3 304 stainless steel stainless steel (*5) 5 304 stainless steel stainless steel (*5) 6 304 stainless steel stainless steel (*5) 7 304 stainless steel stainless steel (*5) 8 304 stainless steel stainless steel (*5) 10 304 stainless steel stainless steel (*5) extra ss tag plate stainless steel elec. housing coating of cell none none none yes none none none none yes yes none yes none yes yes yes yes yes note 4: (*4) available for 13th digit code "y, w, g, a, d". inquire about in case of 13th other code. note 5: (*5) available for all 13th digit code. note 6: (*6) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required, select "yes". note 7: (*7) in case of squre root output mode, squre root scale is not available. note 8: (*8) not available for 10th digit code "c". description note note 7 note 7 note 11 note 14 note 14 note 13 note 13 note 13 note 14 note 4 note 4 note 4 note 4 note 4 note 4 note 4 note 5 note 5 note 5 note 5 note 5 note 5 note 5 note 6 note 8 note 8 digit 10 11 12 4567 123 f0 5 kd 89 10 11 12 13 14 15 21 digit no. of code a c g d h v x k p m r t e j f s u y b m n p q d e l f m n p q r s t v w x (*6) indicator arrester none none analog, 0 to 100% linear scale none analog, 0 to 100% sq. root scale (*7) none analog, custom scale none analog, double scale (linear and sq. root) none none yes analog, 0 to 100% linear scale yes analog, 0 to 100% sq. root scale (*7) yes analog, custom scale yes analog, double scale (linear and sq. root) yes digital, 0 to 100% linear scale none digital, custom scale none digital, 0 to 100% square root scale none digital, 0 to 100% linear scale yes digital, custom scale yes digital, 0 to 100% square root scale yes digital, 0 to 100% linear scale (local configurator unit with lcd display) none digital, custom scale (local configurator unit with lcd display) none digital, 0 to 100% square root scale (local configurator unit with lcd display) none digital, 0 to 100% linear scale (local configurator unit with lcd display) yes digital, custom scale (local configurator unit with lcd display) yes digital, 0 to 100% square root scale (local configurator unit with lcd display) yes 9 a b c d j e f g h k l p m q s n 1 2 3 4 5 6 (*8)
7 treatment fill fluid standard silicone oil standard fluorinated oil degreasing silicone oil oxygen service fluorinated oil (7th digit code "v", "w", "a", "b", "c" and "d") chlorine service fluorinated oil (7th digit code "h", "t") high temp. 250c silicone oil high temp. 300c silicone oil high temp. and vacuum (250c) silicone oil high temp. and vacuum (300c) silicone oil high temp. and high vacuum silicone oil none yes (available for 5th digit code "0", "2", "4", "6", "8", "a", "c", "e", "g", "j", "p", "m", "r", "s", "t", "v", "x" and 7th digit code "v", "w", "j". not available for the 13th digit code "h", "j".) (*10) high accuracy type instruction manual attached low temperature effect type instruction manual attached h+j instruction manual attached instruction manual unattached high accuracy type instruction manual unattached low temperature effect type instruction manual unattached t+u instruction manual unattached note 9: (*9) treatment; standard note 10: (*10) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manual attached. note 11: (*11) available for 4th digit code "s". note 13: (*13) available for 4th digit code "6", "8", "t", "w". note 14: (*14) available for 4th digit code "6", "t". description note note 9 note 10 digit 13 14 21 4567 123 f0 5 kd 89 10 11 12 13 14 15 21 digit no. of code y w g a d h j s t k y c 7th digit code "v", "w", "a", "b", "c", and "d" 7th digit code "v", "w", "a", "b", "c", "d", "h", "f", "g", "k", and "l" (*9) h j k l t u v
8 fkd ... 5 ordering information when ordering this instrument, specify: 1. code symbols 2. measuring range 3. output orientation (burnout direction) when abnormality is occurred in the transmitter. hold / overscale / underscale unless otherwise speci? ed, output hold function is sup- plied. 4. output mode (linear or square root output) unless otherwise speci? ed, output mode is linear. 5. indication method (indicated value and unit) in case of the actual scale (code d, h, p, s ,2 ,5 on 9th digit). 6. tag no. (up to 14 alphanumerical characters), if required.
9 outline diagram (unit:mm) *//&30'("4,&5 4&&5"#-& %&5"*-# $0/%6*5$0//
*/$"4&0'5)%*(*5$0%&5 */$"4&0'5)%*(*5$0%&4 7 8 ;&30"%+4$3&8 .5(1*1&+*4" #
#$0/%6*5$0// &"35)5&3.*/"- .4$3&8 %&15) 1 )? ' -  u & % ( /)0-&4i%*" )1 -1 .9 4              + ,.      ' (     2  & uiejhjupguif dpeftzncpmt  " 4 %  &  (   u  1  / i  '-"/(& +*4," .        +*4,"  $        +*4,"  #        +*4,"  %        +*4,"  & 5        "/4*-##  ( 7        "/4*-## 3 9        "/4*-##  ' 6        "/4*-##  ) 8        "/4*-##  +        %*/1/%/  ,                                %*/1/%/  )0-&4%*" 6#0-5. '-"/(& )? 

8*5)"/"-0(*/% 8*5)%*(*5"-*/% *//&30'("4,&5 uiejhjupguif dpeftzncpmt $poevjudpoo +,. (   /15   1h   .   4 7 8 + ) . 5 1 3  ? "  ? #  ? $  ? %  ? 5 7 8 ."44"11309 lh
5"#-& % 2  & 3  - 4  ' 5  . 7  / 8  1 9  4 n
?8"'&35:1&? " #  " #  2 - uiejhjupguif dpeftzncpmt uiejhjupguif dpeftzncpmt 4uboebse nbufsjbmt tqfdjpdbujpo /puf ' $pssptjpo sftjtubou nbufsjbmt tqfdjpdbujpo /puf ( 015*0/1"354'03'-".&1300'0'5**4 +"1"/
uiejhjudpef$ $bcmfhmboeuzqf
 /05&
$"#-&(-"/%    $$0/%6*5$0// 445"(1-"5& $0//&$5*0/%*"(3". $, $,   /05&
*/$"4&0'5)$0%&?$? $"#-&*446*5#-& ( %&5"*-l$z    /puf
*odbtfpguifuiejhjupguzqfdpefjt7 " # $ % +ps8 /puf
*odbtfpguifuiejhjupguzqfdpefjt) . 5 1ps3
10 fkd ... 5 uiejhjupguif dpeftzncpmt $poevjudpoo +,. (   /15   1h   .    7 8 + ) . 5 1 3  ? "  ? #  ? $  ? %  ?    ."44"11309 lh
*/$"4&0'5)%*(*5$0%& */$"4&0'5)%*(*5$0%&   ;&30"%+4$3&8 .5(1*1&+*4" #
&"35)5&3.*/"- 1 /)0-&4i%*" )1 -1 .9 4                 & 5"#-& % 2  & 3  - 4  ' 5  . 7  / 8  1 9  4 n
?8"'&35:1&? " #  " #  2 - *//&30'("4,&5 .4$3&8 %&15) ' (  2 4&&5"#-& %&5"*-# $0/%6*5$0//
  + ,. *//&30'("4,&5 )? ' & % ( '-"/(&  )0-&4%*" 6#0-5. #$0/%6*5$0// 8*5)"/"-0(*/% 8*5)%*(*5"-*/% 

uiejhjupguif dpeftzncpmt uiejhjupguif dpeftzncpmt -  u uiejhjupguif dpeftzncpmt  " 4 %  &  (   u  1  / i  '-"/(& +*4," .        +*4,"  $        +*4,"  #        +*4,"  %        +*4,"  & 5        "/4*-##  ( 7        "/4*-## 3 9        "/4*-##  ' 6        "/4*-##  ) 8        "/4*-##  +        %*/1/%/  ,                                %*/1/%/ )? 4uboebse nbufsjbmt tqfdjpdbujpo /puf ' $pssptjpo sftjtubou nbufsjbmt tqfdjpdbujpo /puf /puf
*odbtfpguifuiejhjupguzqfdpefjt7 " # $ % +ps8 /puf
*odbtfpguifuiejhjupguzqfdpefjt) . 5 1ps3 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
11 atex ex ii 2 gd ex d iic t6 ip66/67 t85c tamb = ?40c to +65c ex d iic t5 ip66/67 t100c tamb = ?40c to +85c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) seal not required enclosure is allowed. tiis ex do iib+h 2 t4 tamb max = +60c maximum process temp. = +120c iecex scheme ex d iic t5 ip66/67 tamb = ?40c to +85c ex d iic t6 ip66/67 tamb = ?40c to +65c authorities flameproof nepsi ex d iib+h 2 t6 tamb = ?40c to +60c atex ex ii 1 g ex ia iic t5 tamb = C40c to +50c ex ia iic t4 tamb = C40c to +70c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=28v, imax=94.3ma, pi=0.66w, ci=35.98nf, li=0.694mh csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, imax=94.3ma, ci=25nf (without arrester), ci=36nf (with arrester), li=0.6mh (without analog meter), li=0.7mh (with analog meter) tiis ex ia iic t4 tamb max = +60c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=38.4nf, li=0.694mh iecex scheme ex ia iic t4 tamb = C40c to +70c ex ia iic t5 tamb = C40c to +50c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) authorities intrinsic safety model code 9th digit 13th digit a,b,c,d,j y,g,h,j,s,t,k ?40c to +85c l,p,m,1,2,3 y,g,h,j,s,t,k ?20c to +80c q,s,n,4,5,6 y,g,h,j,s,t,k ?20c to +60c e,f,g,h,k y,g,h,j,s,t,k ?40c to +60c ? w,a,d ?10c to +60c tamb model code 9th digit 13th digit a,b,c,d,j y,g,h,j,s,t,k ?40c to +85c l,p,m,1,2,3 y,g,h,j,s,t,k ?20c to +80c q,s,n,4,5,6 y,g,h,j,s,t,k ?20c to +60c e,f,g,h,k y,g,h,j,s,t,k ?40c to +60c ? w,a,d ?10c to +60c tamb nepsi ex ia iic t4 ex d iib+h 2 t6 / ex ia iic t4 entity parameters: ui=42.4v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh atex ex ii 3 gd eex nl iic t5 tamb = ?40c to +50c eex nl iic t4 tamb = ?40c to +70c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=25.18nf, li=0.694mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh eex nal iic t5 tamb = ?40c to +50c eex nal iic t4 tamb = ?40c to +70c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual (pending) class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, ci=25.18nf (without arrester), ci=35.98nf (with arrester), li=0.694mh authorities type n nonincendive model code 9th digit 13th digit a,b,c,d,j y,g,h,j,s,t,k ?40c to +85c l,p,m,1,2,3 y,g,h,j,s,t,k ?20c to +80c q,s,n,4,5,6 y,g,h,j,s,t,k ?20c to +60c e,f,g,h,k y,g,h,j,s,t,k ?40c to +60c ? w,a,d ?10c to +60c tamb table 2
fkd ... 5 printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDSX6-136H

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X